JUMPER JPD-500E pulse oximeter – fingertip SpO2 and pulse measurement
- Stock: In Stock
- Brand: Jumper -en
- Model: 6951740521383
JUMPER JPD-500E pulse oximeter is a practical fingertip device for non-invasive spot-check measurement of blood oxygen saturation — SpO2, pulse rate and pulse strength. It is intended for occasional checking of vital parameters at home, in clinics, medical offices or other healthcare settings when a quick oxygen saturation and pulse reading is needed.
The oximeter is placed on the finger and the result is shown on a digital display. It is compact, lightweight and easy to carry, making it useful for people who need to monitor oxygen saturation and pulse during respiratory symptoms, recovery, chronic respiratory or cardiac conditions, or when home SpO2 monitoring is recommended by a doctor or pharmacist.
When is the JUMPER JPD-500E pulse oximeter used?
JUMPER JPD-500E is used for occasional checking of oxygen saturation and pulse rate. It is important to know that a pulse oximeter does not provide a diagnosis, does not replace medical examination and is not intended for continuous patient monitoring. Results should always be interpreted together with symptoms, general condition and professional medical advice.
- Measures blood oxygen saturation — SpO2.
- Measures pulse rate in beats per minute.
- Displays pulse strength using a bar graph.
- Finger-based, non-invasive measurement without blood sampling.
- Practical for home checks, travel and occasional monitoring.
- Automatic power-off when no signal is detected.
- Powered by 2 AAA batteries.
| Need | Recommended product / category | Purpose |
|---|---|---|
| SpO2 and pulse checking | JUMPER JPD-500E pulse oximeter | For quick fingertip reading of SpO2, pulse rate and pulse strength. |
| Home medical equipment | Medical devices and equipment | Category for home devices used to track selected health parameters. |
| Blood pressure and pulse tracking | Blood pressure monitors | Useful for people who monitor blood pressure and pulse in addition to oxygen saturation. |
| Temperature monitoring | Digital thermometers | Useful when body temperature is monitored together with respiratory symptoms, fatigue or infection. |
How to measure oxygen saturation correctly?
The hand should be still and relaxed, and the finger should be correctly positioned inside the device. Nail polish, gel nails, cold fingers, poor peripheral circulation, movement during measurement or strong ambient light can affect reading accuracy. It is best to wait until the values stabilize and not make decisions based on a single short or unstable reading.
Technical details
| Model | JPD-500E |
| Device type | Fingertip pulse oximeter |
| Parameters | SpO2, pulse rate and pulse strength |
| SpO2 measuring range | 35–100% |
| SpO2 accuracy | ±2% in the 70–100% range; below 70% unspecified |
| Pulse range | 25–250 bpm |
| Power supply | 2 × AAA batteries |
| Automatic power-off | Yes, when no signal is detected |
| Dimensions | approx. 62 × 37 × 32 mm |
| Weight | approx. 50 g with batteries |
Important warning
Low oxygen saturation, breathing difficulty, blue lips, chest pain, confusion, severe weakness, high fever or sudden worsening of general condition require urgent medical evaluation. A pulse oximeter is an auxiliary measuring device and should not delay seeking medical help when serious symptoms are present.
Pharmacist advice
A pulse oximeter is useful for occasional SpO2 and pulse checks, but the result should always be interpreted together with symptoms. If the value is lower than usual, repeat the measurement after a few minutes at rest, check that the finger is warm and correctly positioned, and remove nail polish or artificial nails if they interfere with the reading. In people with chronic lung or heart disease, action thresholds should be defined by a doctor. Do not use a pulse oximeter as a substitute for examination, therapy or professional monitoring when the condition is serious.
Frequently asked questions
What does the JUMPER JPD-500E pulse oximeter measure?
It measures blood oxygen saturation — SpO2, pulse rate and pulse strength through the finger.
Can a pulse oximeter diagnose a disease?
No. A pulse oximeter is an auxiliary measuring device and does not replace medical examination, diagnostic tests or professional assessment.
Why can the result be inaccurate?
Cold fingers, movement, incorrect finger position, nail polish or gel nails, poor circulation and strong ambient light can affect the reading.
Is it used for continuous monitoring?
No. JUMPER JPD-500E is intended for occasional SpO2 and pulse checks, not continuous patient monitoring.
Which batteries does it use?
The device uses 2 AAA batteries.
When should medical help be sought?
Medical help is needed if oxygen saturation is low or if breathing difficulty, chest pain, blue lips, confusion, severe weakness or sudden worsening occurs.
Is it suitable for children?
The JPD-500E instructions describe use in pediatric and adult patients, but readings in children should be interpreted carefully and according to medical advice.
Pharmacy Online has a contract with the Daily Express courier service and it is delivered on the territory of the Republic of Serbia through this service. Exports of goods to foreign countries are done through DHL and PostExport.
For all orders received up to 12h from Monday to Friday, the approximate delivery time is 2-4 business days for the whole territory of the Republic of Serbia. In case the order is placed on weekends (Saturdays and Sundays), the delivery is done as well as for the orders received on Monday - so next business day.
Deliveries are not made on Saturdays and Sundays.
Additional information
The items will be packed so that they cannot be damaged by normal handling of the goods in transit. When picking up the product, the buyer is obliged to check for any damage and immediately advertise it to the courier who delivered the goods, or refuse to take over the shipment, which shows the external damage. Any subsequent product claims for shipping damage will not be considered.
When picking up the product, the customer is required to sign the delivery note taken by the Daily Express delivery worker. The delivery note is considered to be a receipt and delivery note.
The courier service delivers the goods to the address, ie. does not bring into the living space.
Delivery restrictions on goods
Delivery of items purchased on the site www.apotekaonline.rs is made exclusively through the Daily Express courier service in the territory of the Republic of Serbia. Delivery outside the territory of the Republic of Serbia, ie export of goods, is done exclusively through the service of DHL and PostExport Post of Serbia.
Shipping cost
For the territory of the Republic of Serbia:
For goods ordered up to 5.000,00 RSD, delivery charge is 260.00 RSD (VAT included). For goods over 5.000,00 RSD, shipping is free of charge.
For international delivery:
For the export of goods abroad through the PostExport service of Post of Serbia, the shipping price is for:
- Zone I (Slovenia, Croatia, Bosnia and Herzegovina, Montenegro, Northern Macedonia) - 1,280.00 RSD
- Zone II (Other European countries) - 1,790.00 RSD
- Zone III (Asia, Africa, America, Australia and other countries) - 2,650.00 RSD
Delivery time is 15 days or more (depending on the country of delivery)
For export of goods abroad through DHL service, the shipping price is 2,700.00 RSD. Delivery time is 1-5 business days (depending on the country of delivery)
Shipping cost is with tax. The price includes the delivery of the parcel to the buyer's address with the associated tax and customs at the seller's expense. A possible additional cost may be a customs charge against the buyer, depending on the country to which the package is being shipped.
For any additional questions, complaints or checking the current location of your shipment, please contact us at the following e-mail address: info@apotekaonline.rs